steam boiler Agents of 10 kg pressure

Gas Vacuum Boiler Project

Gas Vacuum Boiler Project

The deep matched technology of new combustion and heat transfer no longer sacrifices the boiler's key characteristics to adapt to the burner characteristics, making the gas boiler a complete thermal system with low nitrogen emissions.

Learn More Free Chat
Electric Steam Boiler Project

Electric Steam Boiler Project

The advantage of the electric heating steam boiler is that there is no combustion chamber and no chimney is needed, so the heat loss does not have to be considered, and the thermal efficiency can reach 98% or more.

Learn More Free Chat
Gas Steam Boiler Project

Gas Steam Boiler Project

This series of boilers adopts the design structure of full-membrane wall, and the sealing effect is very good. Multi-layer insulation materials are laid in the transmission pipeline and welding place to minimize the heat loss of the furnace body.

Learn More Free Chat

GET A QUOTE

  • Name:

  • Email:

  • Ton:

  • Phone:

  • Pressure:

Select:

  • Please tell us the type of boiler you need

  • Please tell us the boiler fuel you will use

Requirement:

We will process the information you submit quickly and ensure that your information is completely confidential.

steam boiler Agents of 10 kg pressure

Chemical Regime in Water Quality Management of High

Dec 19, 2009 · The pH level at 250 C has to be 9.1-10 for pressure 61-100 kg/cm2, below 9.1–9.8 for 101-165 kg/cm2 and below 9.1-9.6 for 166-205 kg/cm2. Silica, in ppm to be controlled in such a way in boiler water so that it will be less than 0.02 ppm in steam for pressure range 61-165 kg/cm2.

Free Chat

Part II. Energy Efficiency by Sectors Energy Efficiency in

Water Tube Boilers Used for high pressure high capacity steam boiler Available in sizes that are far greater than the fire tube design. Up to several million pounds per hour of steam. Able to handle higher pressures up to 5,000psig Recover faster than their firetube cousin …

Free Chat

10 th rice husk fired steam boilers

Microtech Boilers Horizontal Husk Fired Steam Boiler Huskpower-Ultra is a Husk Fired Boiler, the next generation rice husk fired boilers from BALKRISHNA, are Working Pressure (kg/Square.cm.g): 20-25, 0-5, 10-15, 5-10, 15-20. rice husk fired steam boiler fuel feeding - YouTube

Free Chat

Steam Boilers - Parker Steam Boilers Latest Price

High pressure steam boiler characteristics: Produce steam above 15 PSIG up to 800 PSIG. Temperatures will exceed 250 degrees F up to 1200 degrees F. May include a superheater to heat steam above saturation temperature. Due to the high pressures and temperatures at which these boilers operate, they need to be monitored to ensure efficient and

Free Chat

10kg pressure steam boiler, 10kg pressure steam boiler

High Pressure Steam Boilers | Lathrop Trotter | Lathrop

Free Chat

Water treatment of steam boilers - SlideShare

Aug 02, 2015 · Medium Pressure (MP) steam boiler = Pressure 10 bar, Temperature = 220o C 3. Low Pressure (LP) steam boiler = Pressure 5 bar, Temperature = 160o C Note: Temperature corresponding to pressure can be found out from standard steam tables Conversion Kg/cm2 g can be converted to psig by multiplying with 14.223 Example A boiler has normal pressure …

Free Chat

Boiler Capacity - Engineering ToolBox

h g = enthalpy steam (Btu/lb, kJ/kg) h f = enthalpy condensate (Btu/lb, kJ/kg) m = steam evaporated (lb/h, kg/s) Boiler Horsepower - BHP. The Boiler Horsepower (BHP) is. the amount of energy required to produce 34.5 pounds of steam per hour at a pressure and temperature of 0 Psig and 212 o F, with feedwater at 0 Psig and 212 o F.

Free Chat

Water treatment of steam boilers - SlideShare

Aug 02, 2015 · Medium Pressure (MP) steam boiler = Pressure 10 bar, Temperature = 220o C 3. Low Pressure (LP) steam boiler = Pressure 5 bar, Temperature = 160o C Note: Temperature corresponding to pressure can be found out from standard steam tables Conversion Kg/cm2 g can be converted to psig by multiplying with 14.223 Example A boiler has normal pressure 12

Free Chat

Steam boilers from Bosch - highly efficient and reliable

Universal steam boiler CSB. Available in six output sizes, from 300 to 5,200 kg/h for pressures ranging between 0.5 and 16 bar. High efficiency rating of up to 95.3% with integrated economiser and helical heat exchanger tubes. Versatile design for use with different fuel types and as a multi-fuel firing unit (oil, gas, biogas, hydrogen)

Free Chat

Steam Calculators: Boiler Calculator

Mar 17, 2015 · Steam, Boiler, and Blowdown Pressure are the same. Combustion Efficiency is the % of fuel energy that is directly added to the feedwater and not otherwise lost or used. Blowdown Rate is the % of incoming feedwater mass flow rate that leaves the boiler as a saturated liquid at boiler pressure.

Free Chat

CONVERSION OF BOILER IN KG/H AND KW

CONVERSION OF BOILER IN KG/H AND KW (Approximate) G.B. and U.S.A. Steam from and at 100°C Boiler HP Kg/h 2.26MJ/kg Metric System Steam from 0°C to 100°C Kg/h 2.26MJ/kg Power In kW 1 5 10 15 20 30 40 50 60 70 80 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 15.65 78 156 235 313 470 626 783 940 1096 1252 1566 2350 3130

Free Chat

Boiler Pressure - an overview | ScienceDirect Topics

Boiler pressure is the key factor for determining the need for a condensate polishing system. With a steam generator plant with low steam pressures (below 40 kg/cm 2), the requirement of the CPU is usually avoided.Hard scale formation and boiler metal corrosion can easily be prevented through FW treatment before sending to the boiler proper.

Free Chat

Steam Boilers - Parker Steam Boilers Latest Price

Capacity: 0-500 kg/hr, 500-1000 kg/hr. Fuel: Oil Fired, Coal Fired, Gas Fired, Oil and Gas Fired. Working Pressure: 20-25 kg/cm2g, 0-5 kg/cm2g. Style: Horizontal. Model: Combi-Tube Manual Fired. Type: Water cum smoke tube boiler, front end radiant twin membrane water wall coupled with shell and tube

Free Chat

Steam Boilers - Biomass Steam Boilers Manufacturer from

Get Latest Price. This Steam Boiler Imported Coal fired Boiler and comes with Auto Coal firing system with Low man power and low maintenance having higher efficiency of boiler. Specifications: Boiler Capacity - 1 TON to 8 Ton Per hr. Boiler Working Pressure - 10.54 to 17.5 kg/cm2. Fuel Feeding - …

Free Chat

Steam explosion - Wikipedia

A common operating temperature and pressure for a marine boiler is around 950 psi (6,600 kPa) and 850 °F (454 °C) at the outlet of the superheater. A steam boiler has an interface of steam and water in the steam drum, which is where the water is finally evaporating due to the heat input, usually oil-fired burners.

Free Chat

Boiler Feed Water Treatment - EWT Water Technology

May 05, 2018 · For each distinct mode of steam boiler operation, there is, with a given steam boiler design and steam boiler operating pressure, a different set of requirements for →boiler feed water and →boiler water quality, thus affecting the choice and design of water treatment processes. ↑ top of page. Make-up Water Treatment

Free Chat

2. BOILERS - Bureau of Energy Efficiency

2. BOILERS Bureau of Energy Efficiency 27 Syllabus Boilers: Types, Combustion in boilers, Performances evaluation, Analysis of losses, Feed water treatment, Blow down, Energy conservation opportunities. 2.1 Introduction A boiler is an enclosed vessel that provides a means for combustion heat to be transferred into water until it becomes heated water or steam.

Free Chat

High Pressure Steam Boilers | Lathrop Trotter | Lathrop

Hf = 182.54 kcal/kg and. Hfg = 481.82 Kcal/kg. Steam with the dryness fraction of 0.95, H =640.27 Kcal/kg. Pressure reducing station is an isenthalpic device (i.e. there is no work done). Hence, 'H' at inlet and outlet is same. With reduced pressure to 3 bar g, Hf = 144.74 kcal/kg and Hfg = 510.29 Kcal/kg.

Free Chat

Steam Boilers - Parker Steam Boilers Manufacturers

Indian Boilers Regulation (IBR) was created in exercise of the powers conferred by section 28 & 29 of the Indian Boilers Act. Typical Boiler Specification Boiler Make & Year: XYZ & 2003 MCR(Maximum Continuous Rating) : 10TPH (F & A 100°C) Rated Working Pressure: 10.54 kg/cm2(g) Type of Boiler: 3 Pass Fire tube Fuel Fired: Fuel Oil

Free Chat

U.S.C.G. Merchant Marine Exam Third Assistant Engineer

o (A) The steam pressure and volume will remain constant. o (B) The pressure will increase and the volume will remain constant. • (C) The pressure will increase and the specific volume will decrease. o (D) The pressure will remain constant and the volume will increase. If choice C is selected set score to 1. 3.

Free Chat